ATX12VO (12V Only) Desktop Power Supply

Design Guide

ID 613768
Date 01/03/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

Closed Loop Stability (Required)

The power supply shall be unconditionally stable under all line/load/transient load conditions including capacitive loads specified in Section 4.2.6. A minimum of 45 degrees phase margin and 10 dB gain margin is recommended at both the maximum and minimum loads.