Fan Requirements (Required)

The fan will draw air from the computer system cavity pressurizing the power supply enclosure. The power supply enclosure shall exhaust the air through a grill located on the rear panel. Refer to Figure 14-7: SFX12V Top Mount Fan, Inside enclosure Mechanical Outline (Possible Larger Fan)

image46.png

Figure 14-8. Moving the fan to the computer system cavity helps to limit the acoustic noise of the unit.

The fan will be 80 mm.

Figure 14-6: SFX12V Reduced Depth Top Mount Fan Profile Mechanical Outline

image47.png

Figure 14-7: SFX12V Top Mount Fan, Inside enclosure Mechanical Outline (Possible Larger Fan)

image48.png

Figure 14-8: SFX12V Chassis Cutout