Intel® Ethernet Adapters and Devices Release Notes

ID Date Version Classification
778690 10/17/2026 Public

1 Intel® Ethernet Controller Products 31.3 Release Notes

This document provides an overview of the changes introduced in the latest Intel® Ethernet Controller/ Adapter family of products. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

These release notes list the features supported in this software release, known issues, and issues that were resolved during release development.

Important:

Starting with the 31.1 release, Intel is publishing the Release Notes in HTML (with an option to download a PDF). To view the PDF Release Notes for past releases, click Intel® Ethernet Controller Products Release Notes., and then from the Version list, select the appropriate version.

For more information about using this family of products, see the Intel Ethernet Adapters and Devices User Guide.

1.1 Overview

The following sections provide an overview of this release.

1.1.1 New Features

Category

Release 31.3

Hardware Support

  • None for this release

Software Features

  • E610:
    • NDIS SR-IOV VF link speed display correction

    • Capability to disable unused ports for PCIe Network Adapter via UEFI HII

    • Timestamp (PTP) support on Windows

    • PHY Synchronization Using 1PPS from MAC

    • Total Port Shutdown

  • E710: Windows Default *FlowControl

  • E800:
    • Virtualization Mode restore to defaults to SR-IOV for Supermicro cards

    • RSS resource sharing between ports

    • RDE Wake-on-LAN ownership of disabling WoL

    • Support multiple input sets for flow steering on single VF

    • Windows Default *FlowControl

  • E810:
    • Clarification and update of NoFECinAuto behavior for UEFI HII

    • Clarification of ForwardErrorCorrection help string for UEFI HII

  • E825: TX Reference Clock Persistent Selection via devlink

  • E830: OEMROT Security Fuse Programming Support

  • E83x: Earliest Time First Offload (SO_​TXTIME) for VFs

  • All models:
    • Dynamic Kernel Module Support

    • FreeBSD - sanitize negative error codes

    • FreeBSD 15.1 and 14.5 OS Support

    • Azure Local 2607 Base Support

Firmware Features

  • E610
    • RDE property Port.Enabled

    • NC-SI Passthrough transmission of the same MAC address from 2 ports

    • Get LLDP Frame Intel OEM NC-SI command

Removed Features

  • DDP Tool Support

  • FreeBSD IXGBE, ICE and IAVF OOT driver support

  • Support for Windows Core OS

  • Advanced Networking Services (ANS)

  • Azure Stack HCI 22H2, 23H2, 24H2

  • RHEL 8.7, 8.9, 9.3, 9.4, 9.5

  • SUSE Linux Enterprise Server 15 SP5

  • FreeBSD 13.5, 14.3

Table 1: New Features

1.1.2 Operating Systems Supported

The following are the supported operating systems.

1.1.2.1 Linux

Operating Systems supported:

  • Linux Kernel 6.x and 5.x

  • Linux Real Time Patch 6.x and 5.x

  • Kylin Linux Advance Server V10 (only for Intel Ethernet E810 Series)

  • Red Hat* Enterprise Linux* (RHEL) 10.2

  • Red Hat* Enterprise Linux* (RHEL) 10.1

  • Red Hat Enterprise Linux (RHEL) 10.0

  • Red Hat Enterprise Linux (RHEL) 9.8

  • Red Hat Enterprise Linux (RHEL) 9.7

  • Red Hat Enterprise Linux (RHEL) 9.6

  • SUSE Linux Enterprise Server 16

  • SUSE Linux Enterprise Server 15 SP7

  • SUSE Linux Enterprise Server 15 SP6

  • Canonical* Ubuntu* 26.04 LTS

  • Canonical Ubuntu 24.04 LTS

  • Canonical Ubuntu 22.04 LTS

  • Debian* 11 (not available for Intel Ethernet E610 Series)

  • openEuler (not available for Intel Ethernet E610 Series)

Product

PF Driver

VF Driver

RDMA Driver

Intel® Ethernet 810/820/830 Series

2.7.6

4.13.78

2.7.74

Intel® Ethernet 700 Series

2.30.83

4.13.78

2.7.74

Intel® Ethernet 10 Gigabit Adapters

6.5.9

5.3.87

Not Supported

Intel® Ethernet Gigabit Adapters

5.20.93

Not Supported

Not Supported

Table 2: Supported Operating Systems: Linux

1.1.2.2 Microsoft Windows Server

Operating Systems supported:

  • Microsoft Windows Server 2025

  • Microsoft Windows Server 2022

  • Microsoft Windows Server 2019, Version 1903

  • Microsoft Windows Server 2016 (Not available for Intel Ethernet E610 Series)

  • Microsoft Azure Stack HCI

  • Microsoft Azure Local

Driver

Windows Server 2025

Windows Server 2022

Windows Server 2019

Windows Server 2016

Intel® Ethernet 800 Series

icea

1.22.78.0

1.22.84.0

1.22.78.0

1.14.104.0

iceb

1.5.80.0

1.5.83.0

1.5.78.0

Not Supported

scea

1.20.83.0

1.20.91.0

1.20.77.0

Not Supported

sceb

1.19.68.0

1.19.74.0

Not supported

Not Supported

Intel® Ethernet 700 Series

i40ea

1.26.82.0

1.26.77.0

1.26.80.0

1.18.369.0

i40eb

1.26.78.0

1.26.80.0

1.26.78.0

1.18.369.0

Intel® Ethernet Adaptive Virtual Function

iavf

1.20.80.0

1.20.72.0

1.20.79.0

1.14.203.0

Intel® Ethernet 600 Series / Intel® Ethernet 10 Gigabit Adapters and Connections

ixs

4.2.7.5

4.2.7.5

4.1.254.0

4.1.254.0

sxa

4.2.9.0

4.1.254.0

4.1.254.0

4.1.254.0

sxb

Not Supported

4.1.254.0

4.1.254.0

4.1.254.0

ixt

Not Supported

Not Supported

4.1.228.0

4.1.229.0

ixn

Not Supported

Not Supported

4.1.254.0

4.1.254.0

ixw

1.9.74.0

1.9.74.0

1.9.74.0

Not Supported

vxs

2.4.1.0

2.4.1.0

2.1.252.0

2.1.232.0

vxn

Not Supported

Not Supported

2.1.252.0

2.1.252.0

Intel® Ethernet 2.5 Gigabit Adapters and Connections

e2f

2.1.5.12

1.1.4.46

1.1.4.46

Not Supported

Intel® Ethernet Gigabit Adapters and Connections

e1r

14.1.29.0

14.1.29.0

14.0.7.0

14.0.6.0

Table 3: Supported Operating Systems: Microsoft Windows Server

1.1.2.3 Microsoft Windows Client

Operating Systems supported:

  • Microsoft Windows 11 25H2

  • Microsoft Windows 11 24H2

  • Microsoft Windows 11 23H2

  • Microsoft Windows 10 21H2

  • Microsoft Windows 10 RS5, Version 1809

Driver

Windows 11

Windows 10 21H2/Windows 10 RS5

Intel® Ethernet 800 Series

icea

1.22.85.0

1.22.78.0

iceb

1.5.79.0

Not supported

Intel® Ethernet 700 Series [1]

i40ea

1.26.86.0

1.26.80.0

i40eb

1.26.76.0

1.26.80.0

Intel® Ethernet 10 Gigabit Adapters and Connections

ixs

4.1.272.0

4.1.254.0

ixt

Not Supported

4.1.228.0

ixn

Not Supported

4.1.254.0

ixw

1.9.74.0

1.9.74.0

vxs

Not Supported

2.1.252.0

vxn

Not Supported

2.1.252.0

Intel® Ethernet 2.5 Gigabit Adapters and Connections

e2fn

2.1.5.12

1.1.4.46

Intel® Ethernet Gigabit Adapters and Connections

e1r

14.1.28.0

14.0.7.0

e1d

12.19.2.68

21H2: 12.19.2.68 RS5: 12.18.9.10

e1dn

20.0.3.28

Not Supported

e1c

Not Supported

Not Supported

v1q

Not Supported

1.4.6.2

Table 4: Supported Operating Systems: Microsoft Windows Client

1.1.2.4 FreeBSD

Operating Systems supported:

  • FreeBSD 15.1

  • FreeBSD 15.0

  • FreeBSD 14.5

  • FreeBSD 14.4

Starting with this release, the out-of-tree (OOT) FreeBSD Physical Function (PF) and Virtual Function (VF) drivers are no longer supported. Release 31.2.2 was the last release to include supported versions of these drivers.

Active development and support for the FreeBSD PF and VF drivers continue through the upstream drivers.

Table 5: Supported Operating Systems: FreeBSD

1.1.2.5 ESXi Drivers

Note:

Intel® ESXi drivers are available from VMware*.

Operating Systems supported:

  • VMWare ESXi 9.1

  • VMWare ESXi 9.0

  • VMWare ESXi 8.0

Refer to VMWare’s download site for the latest ESXi drivers for Intel® Ethernet® devices.

1.1.2.6 NVM Versions Supported

The following table shows the NVM versions supported in this release.

Product

NVM Version

810 Series

E810

5.10

820 Series

E822

3.44

E823-C

3.44

E823-L

3.44

825 Series

E825

4.14

835 Series

E835

2.20

830 Series

E830

2.20

700 Series

X710

9.58

X722

6.50

600 Series

E610

1.70

500 Series

X550

3.70

X552NS

2.10

X552DE

2.10

X553

2.10

200 Series

I210

2.00

I225

1.00

Table 6: NVM Versions Supported

1.1.2.7 DDP Versions Supported

The following table shows the DDP versions supported in this release.

Package

DDP Version

OS Package

1.3.59.0

Comms Package

1.3.63.0

Wireless Edge Package

1.3.28.0

Table 7: DDP Versions Supported

1.2 Fixed Issues

The following issues are fixed in this release.

1.2.1 Intel® Ethernet 800 Series Network Adapters

1.2.1.1 Intel® Ethernet 810 Series

1.2.1.1.1 General
  • None in this release.

1.2.1.1.2 Firmware/NVM/NVM Update
  • None in this release.

1.2.1.1.3 Linux
  • None in this release.

1.2.1.1.4 FreeBSD Driver
  • None in this release.

1.2.1.1.5 Windows Driver
  • Enhancements to completion path correctness and stability, doorbell behavior adjustments, queue/ring concurrency hardening, better error propagation mechanisms. [15018815760]

1.2.1.1.6 Windows Server
  • None for this release.

1.2.1.1.7 ESX Driver
  • None for this release.

1.2.1.1.8 Pre-Boot
  • Added SMBIOS Type 9 SegmentGroupNum to check that the logic matches the SMBIOS structure with the NIC instance. [15019458988]

1.2.1.2 Intel® Ethernet 820 Series

1.2.1.2.1 General
  • None for this release.

1.2.1.2.2 Firmware/NVM/NVM Update
  • None for this release.

1.2.1.2.3 Linux Driver
  • None for this release.

1.2.1.3 Intel® Ethernet 825 Series

1.2.1.3.1 Windows Driver
  • None for this release.

1.2.1.3.2 Firmware/NVM/NVM Update
  • Module FINISAR CORP.FTRJ8519P1BNL is unable to regain link after issuing a link reset. Recovery requires removing the module from both E825 and switch to reacquire link. [22021219549]

1.2.1.4 Intel® Ethernet 830 Series

1.2.1.4.1 General
  • In certain situations, the module temperature read fails to return a valid value, triggering a module error message. The new temperature implementation is fully reworked to function asynchronously from the request. [15019523533]

1.2.1.4.2 Linux Driver
  • User may observe results in WARN_​ON call trace and “unable to move VSI idx 1 into aggregator 1 node”, when using the devlink reload command in ICE Linux driver. [22020980371]

1.2.1.4.3 Firmware/NVM/NVM Update
  • None for this release.

1.2.1.4.4 FreeBSD Driver
  • Due to an error in the FreeBSD ice-2.1.8 component archive build process, it lacks the latest version of the Dynamic Device Personalization package. To avoid entering Safe Mode and limiting adapter functionality, use the DDP package included in the FreeBSD OS. [21044824146]

1.2.1.4.5 ESX Driver
  • None in this release.

1.2.1.4.6 Windows Driver
  • None in this release.

1.2.1.4.7 Pre-Boot
  • Added SMBIOS Type 9 SegmentGroupNum to check that the logic matches the SMBIOS structure with the NIC instance. [15019458988]

1.2.2 Intel® Ethernet 700 Series Network Adapters

1.2.2.1 General

  • None for this release.

1.2.2.2 Linux Driver

  • None in this release.

1.2.2.3 Firmware/NVM/NVM Update

  • None in this release.

1.2.2.4 Windows Driver

  • None for this release.

1.2.2.5 ESX Driver

  • None for this release.

1.2.2.6 Pre-boot

  • None for this release.

1.2.3 Intel® Ethernet I211/I210 Series Network Adapters

1.2.3.1 General

  • None for this release.

1.2.4 Intel® Ethernet 610 Series Network Adapters

1.2.4.1 General

  • None for this release.

1.2.4.2 Firmware/NVM/NVM Update

  • Device Serial Number appears in reverse order in RDE PCIeDevice.SerialNumber property when programmed through EEUpdate tool. [21044636972]

  • When teaming 1 G/100 M ports with link-level flow control enabled, a hang of the transmit path can occur under a heavy load. A reset of the device is required to resume operation. [22022210691]

  • ethtool shows enabled/inactive EEE status even when EEE is established. [16030265052]

1.2.4.3 Windows Driver

  • Speed and duplex values set on PF may not be properly displayed on VF. It’s related only to 100 MB and 1 G speed. [18038848471]

  • On Windows, Energy Efficient Ethernet (EEE) may be incorrectly reported as “Not Supported” in Intel Ethernet Cmdlets, despite EEE functionality being present. [16029901801]

1.2.4.4 Linux Driver

  • Users shall not use pins on /dev/ptpx character device or the PHC periodic output / input interface. [16031572675]

  • The driver fix prevents the MAC address refresh mechanism introduced in driver version 6.4.4 from overwriting a bond slave’s MAC address with its original hardware MAC address. [15019601308]

1.2.4.5 VMware Driver

  • None in this release.

1.2.4.6 ESX Driver

  • None in this release.

1.2.5 Intel® Ethernet I350 Series Network Adapters

1.2.5.1 Linux Driver

  • Kernel calls netpoll with 0 as an internal contract indicating that only Tx path is supposed to be cleared. Stop igb driver from attempting to receive packets from netpoll when called with 0 budget. [15019784014]

1.2.6 Intel® Ethernet 500 Series Network Adapters

1.2.6.1 General

  • None in this release.

1.3 Known Issues

1.3.1 Intel® Ethernet 800 Series Network Adapters

  • Cannot initialize DPDK iavf for large vf queues with OOT PF drivers. [21044564975]

1.3.1.1 Intel® Ethernet 810 Series

1.3.1.1.1 General
  • Windows Server 21H1 OS is unable to save memory dump (crash dump) on disk. It is considered to be an OS defect. [18014988594]

  • DPDK traffic is stopped after FLR reset. This issue has been documented in the rte_​eth_​dev_​reset API. [16018959537]

    Workaround: testpmd can be used to recover a VF after a reset.

  • When a VF reset happens, testpmd will print out “port reset” event to the console.

  • Use the “port reset” command to call rte_​eth_​dev_​reset, and everything will go back to normal

1.3.1.1.2 Firmware/NVM/NVM Update
  • The firmware aligns to DMTF spec clarification. The port schema defines that all the LLDPRecieve sub-properties shall not be present in the resource if the property was not received. [15019109850]

1.3.1.2 Pre-Boot

  • None for this release.

1.3.1.2.1 Linux
  • East-West (VF-VF) traffic fails when using switchdev SR-IOV link aggregation (LAG) in active-backup mode [16029737566]

  • Configuration of a link down on PF0 in LAG mode resulted in a rping test failure. [15018677889]

  • The system crash is observed when user is changing ring size (ethtool -G) when Jumbo frames are enabled (MTU 9000) with traffic present. [22021169950]

  • When user sets more than 8 VLANs for trusted VF, and then moves VF as untrusted, the VLAN configuration will be lost. [18032096535]

    Workaround: To avoid losing VLAN configuration, user shall first reduce VLANs configuration allowed for untrusted VF (not more than 8 VLANs per VF), and then switch the VF to untrusted mode.

1.3.1.2.2 FreeBSD Driver
  • On a Linux host, iavf interfaces in FreeBSD-13.0 guests may experience poor receive performance during stress. [18019784282]

    Workaround: The workaround for this behavior is to do the power cycle of the setup to see the assigned DCB-MAP is reflecting.

1.3.1.2.3 RDMA Driver
  • None for this release.

1.3.1.2.4 VMware Driver
  • None for this release.

1.3.1.2.5 Windows Driver
  • None for this release.

1.3.1.2.6 ESX Driver
  • VF-to-PF and PF-to-VF traffic may fail intermittently when SR-IOV Trusted Mode is used with ENS on ESXi. [18040914960]

    Workaround: Avoid ENS + SR-IOV Trusted Mode combinations in production/cert flows; use a supported networking mode until VMware support is available (targeted with newer VCF stack).

  • Running Unreliable Datagram (UD) RDMA mixed traffic with more than 2 QPs may lead to a receiver side UD application hang. [18015677916]

    Workaround: Restart the RDMA UD application. This is not expected to impact storage (NVMeoF, iSER, VSAN) applications since they do not rely on UD communication.

  • <VMWARE> When instantiating the maximum number of VFs in NSX-T, adding a Transport Node afterwards might fail due to timeout. [18021236660]

  • DDP updates triggered from ENS uplink ports on mixed mode devices may take longer due to extended driver recovery, and the workaround is to wait a minimum of 30 seconds before issuing any subsequent DDP commands. [16029636950]

1.3.1.3 Intel® Ethernet 820 Series

1.3.1.3.1 General
  • None for this release.

1.3.1.3.2 Firmware/NVM/NVM Update
  • After advertising the link to 1G in the MRVL system, the link down and up happened 2 times in SUT and a single time in TG. [16022825930]

  • Using the EPCT tool to change the port configuration requires 2 reboots to complete the programming process. Blank mode or PTP initialization failures may be observed after a single reboot and will be resolved after performing a second reboot. [16021278765]

  • When loading the ICE driver with cages populated, the system displays the error message “Module is not present.” [1509371756]

  • When 100 MB option is selected in Windows Device Manager, a link cannot be established. [18017637026]

  • Lane Reversal is broken preventing proper functionality of 2x1x50g port option on quad 1. CPI opcode 0x67 PortLaneOrder does not support setting lane 1 as the autoneg lane and returns error code 1 (Configuration Error). [22016503876]

1.3.1.3.3 Linux Driver
  • ethtool gives an invalid argument error when using ethtool -m <interface>. [22021254023]

  • Tx Clock Source Selection (NVM) - Feature Not Supported. Tx Clock Source selection is not fully implemented and validated in this release. Configuration of the Tx Clock Source through software interfaces is not supported. To ensure correct device operation, the Tx Clock Source field (Port Options 1, bits [15:14]) must remain set to the default value of 0x3 (“Do Not Change”). Customers should not modify the Tx Clock Source setting and should not rely on non-default values. Any software or management tool capable of modifying this field should not be used to select an alternate Tx Clock Source. Using values other than 0x3 may result in undefined behavior, including link bring-up failures, PHY communication errors, or system instability. [15019916102]

Workaround: Keep Port Options 1[15:14] = 0x3 (“Do Not Change”). Do not use Tx Clock Source configuration in this release. Do not use software or management tools to select a non-default Tx Clock Source. Future releases will provide full support and documented usage requirements.

1.3.1.3.4 FreeBSD Driver
  • None for this release.

1.3.1.3.5 Windows Driver
  • None for this release.

1.3.1.3.6 ESX Driver
  • Multiple PF resets cause VMXnet3 adapter VFs in ENS mode to fail sporadically, resulting in no traffic. [18038466648]

1.3.1.4 Intel® Ethernet 825 Series

1.3.1.4.1 General
  • On Azure Stack HCI 23H2, Event Log reports Error 289 during execution of hyperv.basic.large_​send_​offload_​vf. This behavior is unexpected and is currently under investigation. [15016108905]

1.3.1.4.2 Firmware/NVM/NVM Update
  • CISCO-OPLINK TRMTFEAS1CCISE1G shows link with no fiber connected. [22021216529]

  • NC-SI Health Status 0x508 / 0x507 is not generated, when Global Health Status is enabled. [18042250212]

  • Inconsistencies in LED behavior during system shutdown for E825-C under S5 state when using PV LEK with “NO MNG” configuration. [22021342973]

1.3.1.4.3 Linux Driver
  • It is observed that forcing link speed to 1GbE for e823 with fibre optics cable causing netlink errors. [18042136652]

  • It is observed that Traffic Classes for Tx queues are set to ZERO, when the DCB is configured and traffic with VLANs are sent. [16027773606]

  • The dmesg log shows “link settings prevent physical link to set to OFF” when unplugging multiple cables at once. This issue seems to be limited to SFP and is under investigation. [22020900546]

  • Intermittent PTP “send sync failed” can occur in Boundary Clock mode due to host-side timestamp delivery delays (observed with OS workqueue contention). [16030313929]

    Workaround: Use host configurations that minimize workqueue/graphics-driver interference during PTP runs, monitor for mgag200/EDID-related CPU hogging, and avoid affected host setups for timing-critical BC validation.

1.3.1.4.4 ESX Driver
  • No traffic (ICMP, tcp, udp) after VF reset with NSX-T and DS configuration. [18041512300]

  • After enabling PCI passthrough on different adapter there is no traffic. [18041539956]

1.3.1.5 Intel® Ethernet 830 Series

1.3.1.5.1 General
  • Large number of UDP threads can cause traffic to go to very low throughput. [22020878880]

1.3.1.5.2 Firmware/NVM/NVM Update
  • The firmware aligns to DMTF spec clarification. The port schema defines that all the LLDPRecieve sub-properties shall not be present in the resource if the property was not received. [15019109850]

  • Sysfs ‘ echo 1 > /sys/bus/pci/devices/<PCI BUS address>/remove’ command might cause the order the devices probed to change. If this is the case, the subsequent ice driver probe attempts might end up in kernel WARNING around PTP initialization, if removed PCI device is PF0. PF0 is usually a source timer owner for the devices handled by ice driver (like E825C or E830 devices) and it is a control PF for other PFs. So, non-PF0 devices require PF0 to be initialized first for a successful initialization. [16027730521]

    Workaround: If the current device probe order is disturbed, the user needs to remove all other PFs as well (PF0 as the first one) and rescan PCI bus then.

1.3.1.6 Pre-Boot

  • None for this release.

1.3.1.6.1 Linux Driver
  • When certain DCB settings are enabled on E835 CQDA2 adapters, LAN and RDMA traffic may stop working, including on bonded interfaces. [21045537059]

  • When an Intel E835 adapter is configured in 8×25G breakout mode, some 802.3ad bonds may fail to aggregate both 25GbE links and report 25Gb/s instead of 50Gb/s. [16031579155]

  • In E835 LAG active-active configurations, RoCEv2 traffic may trigger driver hang. [15019771341]

  • PTP synchronization may not converge at 200 GbE. On Intel Ethernet Controller E835-CC QSFP adapters operating in 200 GbE mode, PTP time synchronization in slave mode may fail to converge. This can prevent the system clock from stabilizing to the selected PTP master. PTP synchronization operates as expected at 25 GbE, 50 GbE, and 100 GbE. [22022048555]

  • There is issue with changing msix_​eth value via devlink param interface - some settings of it on E830 cards cause bandwidth degradation. [22021080345]

  • Flow Director rules are not working properly on Geneve Tunnel. Traffic is redirected to random queue. [16024525933]

  • When CRC strip and VLAN strip co-exist, the user may observe a call trace in dmesg. [16025390212]

1.3.1.6.2 FreeBSD Driver
  • Setting E830 and XXVDA2 OCP to only advertise 10G triggers AHS messages about failed link attempts before link comes up. [14022546016]

  • ucmatose fails with RDMA_​CM_​EVENT_​UNREACHABLE (-60) on XXVDA2 OCPwhen running with -c 15000 connections. [18040525298]

1.3.1.6.3 RDMA Driver
  • None for this release.

1.3.1.6.4 ESX Driver
  • When loading a DDP package in ENS or ENS Interrupt mode, a warning log and intermittent ping failures may be observed. [16029517816]

    Workaround: Adding a 1-minute delay after loading the DDP package resolves the issue.

  • <VMWARE> When instantiating the maximum number of VFs in NSX-T, adding a Transport Node afterwards might fail due to timeout. [18037659908]

1.3.1.6.5 Windows Driver
  • TX counters are missing on Dell switches when PFC is enabled. Retrace counters are observed on hosts during testing, even with different PFC bandwidth allocations (50/50 split) [18041177557]

1.3.1.6.6 QV Tools
  • Switching the port option from 8x25 to 2x1x100 using EPCT causes a BSOD approximately 2 minutes after the command is issued, resulting in a shutdown. [22022712629]

    Workaround: Reboot the system immediately after changing the port option to prevent this. Other port option transitions do not trigger the BSOD.

1.3.2 Intel® Ethernet 700 Series Network Adapters

1.3.2.1 General

  • None for this release.

1.3.2.2 Intel® Ethernet Controller V710-AT2/X710-AT2/TM4

  • Upon unloading the i40e driver when some VFs are assigned to VM before it fully operates may cause the VF to hang. To avoid the VF from hanging, destroy the VFs before unloading i40e Linux driver. [22019028699]

1.3.2.3 Linux Driver

  • Cannot initialize DPDK iavf for large vf queues with OOT PF drivers [22022222272]

  • In some cases ./nvmupdate64e can’t initialize the XL710 card in recovery mode: [13011806960]

    Intel® Ethernet NVM Update Tool NVMUpdate version 1.41.3.1 Copyright © 2013 - 2024 Intel Corporation. Config file read. Warning: Cannot initialize port: [00:059:00:00] Intel® Ethernet Converged Network Adapter XL710-Q2 Warning: Cannot initialize port: [00:059:00:01] Intel® Ethernet Controller XL710 Generic ID

  • Changing the inner or outer VLAN tag protocols after setting the private flag “vf-true-promiscsupport” disables the promiscuity on the VF’s VLAN interfaces. [18026565857]

1.3.2.4 Pre-Boot

  • None for this release.

1.3.2.5 ESX Driver

  • None for this release.

1.3.2.6 Firmware/NVM/NVM Update

  • Improved link initialization when Low Power Link Up (LPLU) is enabled, reducing setup time from approximately one minute to a few seconds. [15019600387]

  • AutoSpeedNegotiationEnabled property returns current status of the Autonegotiation from the link, not the configured value to control AN. [15016417165]

  • After updating to NVM 4.11 in some servers, one port of X557/X527 OCP adapter appears link down from Windows Device Manager after reboot. (disabling SR-IOV increases repro rate) [1508313580]

    Workaround: Link status is restored back to normal after unplug/plug cable or disable/enable the affected port from Windows Device Manager.

  • NVM content might be corrupted after nvmupdate due to old FW version generating errors. In this cases “i40e: eeprom check failed (-5), Tx/Rx traffic disabled” will appear. [15016157644]

1.3.2.7 Windows Driver

  • X710 has changed the value of DMAR “DmaRemapping in Windows 11 (value == 1)” due to BSOD. [15017340700]

1.3.2.8 ESX Driver

  • When MTU is set to 9000, sending ICMP packets larger than 1500 bytes between ESXi hosts may occasionally trigger Receive Oversize Errors on the receiving side; this issue is rare and was observed only in one setup. [16027856645]

1.3.3 Intel® Ethernet 600 Series Network Adapters

1.3.3.1 General

  • It may be possible that invalid PCIe configuration can cause that EEUpdate will not show the adapter in OS. [18040371079]

1.3.3.2 Linux Driver

  • For 100 Mbit and 1 G speeds, the PTP synchronization will archive only ~low double-digit nanosecond precision. [16028142000]

  • SLES 15SP6 - NIC ports may not be initialized via NVM Update Tool (via inventory switch). Devlink can be used instead - which is accessible by nvmupdate - if devlink flag. [18039533944]

1.3.3.3 Windows Driver

  • When Total Port Shutdown is enabled and the adapter is disabled before a system reboot, the device may be reported as “Not Present” after the reboot. Despite the reported status, the device can be enabled as usual. [14028771838]

  • When the link partner (client) changes its speed from 1 Gbps down to 100 Mbps or from 100 Mbps to 1 Gbps, autonegotiation on the Physical Function (PF) does not complete correctly, and the PF fails to settle on the expected link speed. As a result, the reported/actual link speed on the system under test does not match the speed configured on the link partner. [21045182704]

    Workaround: Set the link partner first to 2.5 Gbps or to auto-negotiation, then change it to the desired 100 Mbps or 1 Gbps.

  • On quad-port adapters, sporadic interface reset or disconnect events may be observed during SR-IOV stress testing when the maximum number of VFs is allocated on each port and all VFs are restarted simultaneously without any delays. When this issue occurs, Windows Event Viewer may report Event ID 10400, and some VFs may enter a degraded state, and a PF reset is required to recover the affected VFs. [22021911795]

  • On Windows Server 2025 VMs, configuring RSS parameters in rapid succession by script may cause VM crashes (BSOD). [18044201644]

    Workaround: To avoid the issue, add a delay (sleep) between each configuration step.

  • If two vNICs are connected through a vSwitch and the adapter is unexpectedly removed, the network connection may be lost. Restoring connectivity might require reinstalling the driver or rebooting the system. [18040051448]

1.3.3.4 VMware Driver

  • None for this release.

1.3.3.5 Firmware/NVM/NVM Update

  • An abnormal LED indecision may be absorbed where the LED will stay on even if the cable is disconnected, files that were released after E610 version 1.5 may be impacted, this have been fixed and should be part of the next major release after E610 version 1.7. [21044652728]

  • Two link-down events are observed after link speed changes to 1 G and 10 G. However, the link is established correctly. [18040993086]

  • Firmware may occasionally respond with ERROR_​NOT_​READY to GetFirmwareParameters PLDM command after power cycle for extended period of time (15+ seconds). [15019168824]

  • PLDM GetSensorReading for Link Speed sensor returns value 0 when link speed is 100M/2.5G/5G, but shows proper value at 1G/10G. [13015151139]

  • RDE Port.MaxFrameSize shows lower value than expected when system is in S5 power state. [13014542458]

  • Value of RDE property Port.FlowControlStatus is not updated after PATCH to Port.FlowControlConfiguration. [13013713472]

  • After NVM Update from Firmware Recovery mode, additional NVM Update is required for adapter to get back into operational state. [18041922895]

  • Once NVM is updated via NVM Update Tool, it might be possible that target image is not loaded yet. If such situation occurs then warm reset (reboot) is required, then target image will be fully loaded. [18040950466]

1.3.3.6 ESX Driver

  • None for this release.

1.3.4 Intel® Ethernet 500 Series Network Adapters

  • For X550 Windows Driver design, vectors 0 through 7 are enabled at driver init and all RSS queues and queues form various TCs are mapped to it. But more vectors are available to use (GetVectorsAvailableForRssQueues = 16 , NumRssQueues = 8). After getting an RSS indirection table update, a new vector outside of 0 to 7 range can be chosen for a queue while doing the queue to CPU remapping process. If that vector is outside of the 0-7 range, current design will have trouble for the queue to CPU remapping process and cause 10400 event. [15015966177]

    Workaround: Change RSS processor count & queue count max/default value to 8 to align with max 8 queue mapping support on driver to avoid issue.

  • Intermittent Traffic Delivery Failure on SLES 15 SP5/SP6 with VF Connected to SW Bridge: an issue has been identified in SLES 15 SP5/SP6 where network traffic from a Virtual Function (VF) connected to a software bridge (SW bridge) may intermittently fail to reach the intended client. This problem is impacting the reliability of network communications in virtualized environments utilizing software bridges.

    Result: traffic from vf connected to SW bridge sometimes may not reach a client. [18037781233]

1.3.5 Intel® Ethernet I350 Series Network Adapters

  • None for this release.

1.3.6 Legacy Devices

  • None for this release.

1.4 NVM Upgrade/Downgrade 800 Series/700 Series/600 series and X550

Refer to the 1.6.1   Feature Support Matrix (FSM) links listed in Feature Support Matrix for more detail. FSMs list the exact feature support provided by the NVM and software device drivers for a given release.

1.5 Languages Supported

Note:

This only applies to Microsoft Windows and Windows Server Operating Systems.

This release supports the following languages:

  • English

  • French

  • German

  • Italian

  • Japanese

  • Spanish

  • Simplified Chinese

  • Traditional Chinese

  • Korean

  • Portuguese