Intel® 400 Series Chipset On-Package Platform Controller Hub
Online Register Database
| ID | Date | Version | Classification |
|---|---|---|---|
| 615146 | 08/09/2019 | 1.2 | Public |
Force Event Register for AUTO CMD Error Status (ForceEventforAUTOCMDErrorStatus) – Offset 50
| Bit Range | Default | Access | Field Name and Description |
|---|---|---|---|
| 14:8 | - | - | Reserved
|
| 7 | 0h | RO | Force Event for Command Not Issued by AUTO CMD12 Error (forcecmd_notissuedby_autocmd12_err) 1 – Interrupt is generated0 – No Interrupt |
| 6:5 | - | - | Reserved
|
| 4 | 0h | RO | Force Event for AUTO CMD Index Error (forceautocmdindexerr) 1 – Interrupt is generated0 – No Interrupt |
| 3 | 0h | RO | Force Event for AUTO CMD End Bit Error (forceautocmdendbiterr) 1 – Interrupt is generated0 – No Interrupt |
| 2 | 0h | RO | Force Event for AUTO CMD Timeout Error (forceautocmdcrcerr) 1 – Interrupt is generated0 – No Interrupt |
| 1 | 0h | RO | Force Event for AUTO CMD Timeout Error (forceautocmdtimeouterr) 1 – Interrupt is generated0 – No Interrupt |
| 0 | 0h | RO | Force Event for AUTO CMD12 Not Executed (forceautocmdnotexec) 1 – Interrupt is generated0 – No Interrupt |