ATX12VO (12V Only) Desktop Power Supply

Design Guide

ID 613768
Date 01/03/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

Other Low Power System Requirements (Required)

To help meet multiple world-wide Energy Regulations the +5VSB standby rail must meet the following efficiency as shown in Table 4-5 which is measured with the main outputs off (PS_​ON# high state). These World-Wide Energy Regulations and standards include: Blue Angel* system requirements, RAL-UZ 78, US Presidential executive order 13221, ENERGY STAR*, ErP Lot 6 requirements (2010 and 2013 levels), and 2014 ErP Lot 3 requirements. Additionally, if any Computers use an Alternative Low Power Mode (ALPM) then the +5VSB standby efficiency has similar requirements as shown below.

Table 4-5: Required System DC and AC Power Consumption

12VSB

Load Target

12VSB

Actual Load

Efficiency Target (Both 115V and 230V Input)

Remark

Max / Label

1.5 A / Label

75%

Recommend

0.625 A

75%

REQUIREDALPM and ErP Lot 3 2014

400 mA

75%

Recommend

230 mA

75%

REQUIREDALPM and ErP* Lot 3 2014

38 mA

55%

Recommend

19 mA

45%

REQUIREDErP* Lot 6 2013