ATX Version 3.0 Multi Rail Desktop Platform Power Supply

Design Guide

ID 336521
Date 02/01/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

Thermal Shock (Shipping) - RECOMMENDED

  • Non-operating -40 °C to +70 °C
  • 15 °C/min ≤ dT/dt ≤ 30 °C/min
  • Tested for 50 cycles; Duration of exposure to temperature extremes for each half cycle shall be 30 minutes.