ATX Version 3 Multi Rail Desktop Platform Power Supply

Design Guide

ID 336521
Date 11/01/2023
Public
Document Table of Contents

Mechanical Shock – RECOMMENDED

  • Non-operating 50 g, trapezoidal input; velocity change ≥ 170 in/s
  • Three drops on each of six faces are applied to each sample.