ATX12VO (12V Only) Desktop Power Supply

Design Guide

ID 613768
Date 05/01/2024
Public
Document Table of Contents

Fan Requirements (Required)

The fan will draw air from the computer system cavity pressurizing the power supply enclosure. The power supply enclosure shall exhaust the air through a grill located on the rear panel. Refer to Figure 14-7: SFX12V Top Mount Fan, Inside enclosure Mechanical Outline (Possible Larger Fan)

image52.png

Figure 14-8. Moving the fan to the computer system cavity helps to limit the acoustic noise of the unit.

The fan will be 80 mm.

Figure 14-6: SFX12V Reduced Depth Top Mount Fan Profile Mechanical Outline

image53.png

Figure 14-7: SFX12V Top Mount Fan, Inside enclosure Mechanical Outline (Possible Larger Fan)

image54.png

Figure 14-8: SFX12V Chassis Cutout

image55.png