ATX12VO (12V Only) Desktop Power Supply
Design Guide
Voltage Hold-Up Time – REQUIRED/RECOMMENDED
The power supply shall maintain output regulations per Table 4-2 despite a loss of input power at the low-end nominal range-115 VAC / 47 Hz or 230 VAC / 47 Hz according to Table 4-8.
Table 4-8: Voltage Hold-Up Time
Criteria | REQUIRED | RECOMMENDED |
Output Loading | 100% of Full Load | 80% of Full Load |
Time (T5 + T6) | 12 ms | 17 ms |