Intel® Core™ Ultra Processor

Datasheet, Volume 1 of 2
Supporting Intel® Core™ Ultra Processor for U/H/U-Type4-series Platforms, formerly known as Meteor Lake

ID Date Version Classification
792044 03/05/2024 Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

VCC Voltage Identification (VID)

Intel processors/chipsets are individually calibrated in the factory to operate on a specific voltage/frequency and operating-condition curve specified for that individual processor. In normal operation, the processor autonomously issues voltage control requests according to this calibrated curve using the serial voltage-identifier (SVID) interface. Altering the voltage applied at the processor/chipset causing operation outside of this calibrated curve is considered out-of-specification operation.

The SVID bus consists of three open-drain signals: VIDSCK, VIDSOUT, and VIDALERT# to both set voltage-levels and gather telemetry data from the voltage regulators. Voltages are controlled per an 8-bit integer value, called a VID, that maps to an analog voltage level. An offset field also exists that allows altering the VID table. Alert can be used to inform the processor that a voltage-change request has been completed or to interrupt the processor with a fault notification.

For VID coding and further information, refer to the IMVP9.2 PWM Specification and Serial VID (SVID) Protocol Specification .