ATX Version 3.0 Multi Rail Desktop Platform Power Supply
Design Guide
AC Input - REQUIRED
Table 4-1 lists AC input voltage and frequency requirements for continuous operation. The power supply shall be capable of supplying full-rated output power over two input voltage ranges rated 90-135 VAC and 180-265 VAC rms nominal. The correct input range for use in a given environment may be either switch-selectable or auto-ranging. The power supply shall automatically recover from AC power loss. The power supply must be able to start up under full loading at 90 VAC.
Table 4-1. AC Input Line Requirements
Parameter | Minimum | Nominal1 | Maximum | Unit |
Vin (115 VAC) | 90 | 115 | 135 | VACrms |
Vin (230VAC) | 180 | 230 | 265 | VACrms |
Vin Frequency | 47 | - | 63 | Hz |