Eagle Stream Platform

Data Sheet

ID Date Version Classification
814095 04/04/2025 001 Public
Document Table of Contents

Power and Ground Lands

All lands must be connected to their respective processor power planes, while all VSS lands must be connected to the system ground plane.

For clean on-chip power distribution, processors include lands for all required voltage supplies. These are listed in the following table.

Power and Ground Lands

Power and Ground Lands Comments
VCCIN

Power input to FIVR powered by VR 14 on board.

VCCIN voltage controlled by CPU's SVID Bus signals.

VCCINFAON Power supply for the early on domains.
VCCFA_​EHV Power supply for the PCIe5, UPI IOs and all other FIVR.
VCCFA_​EHV_​FIVRA Power supply for the analog IO FIVR.
VCCD_​HV Power supply for all processor DDR5 memory controllers.
VCCVNN Power supply for the on-PKG device, CPU GPIOs for the future drop-in compatible CPU and platform GPIOs.
VCC_​3P3_​AUX Power supply for the on package devices.
HBM_​VPP Power supply for HBM_​VPP pins as a charge pump voltage for on-package HBM. For non-HBM SKUs, HBM_​VPP pins are NC Inside the package.
VSS Ground