ATX Version 3.0 Multi Rail Desktop Platform Power Supply
Design Guide
Closed Loop Stability - REQUIRED
The power supply shall be unconditionally stable under all line/load/transient load conditions including capacitive loads specified in Section Section 4.2.6. A minimum of 45 degrees phase margin and 10 dB gain margin is recommended at both the maximum and minimum loads.