ATX Version 3.0 Multi Rail Desktop Platform Power Supply

Design Guide

ID 336521
Date 01/02/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

Overshoot at Turn-On / Turn-Off – REQUIRED

The output voltage overshoot upon the application or removal of the input voltage, or the assertion/de-assertion of PS_​ON#, under the conditions specified in Table 4-2, shall be less than 10% above the nominal voltage. No voltage of opposite polarity shall be present on any output during turn-on or turn-off.