ATX Version 3.0 Multi Rail Desktop Platform Power Supply

Design Guide

ID 336521
Date 01/02/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

International – REQUIRED

The vendor must provide a complete CB certificate and test report to IEC 60950-1. The CB report must include ALL CB member country national deviations as appropriate for the target market. All evaluations and certifications must be for reinforced insulation between primary and secondary circuits.

The power supply must meet the RoHS requirements for the European Union, Peoples Republic of China and other countries which have adopted the RoHS requirements for banned materials.