ATX Version 3.0 Multi Rail Desktop Platform Power Supply

Design Guide

ID 336521
Date 01/02/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

Labeling and Marking - RECOMMENDED

The following is a non-inclusive list of suggested markings for each power supply unit. Product regulation stipulations for sale into various geographies may impose additional labeling requirements.

Manufacturer information: manufacturer's name, part number and lot date code, etc., in human-readable text and/or bar code formats.

Nominal AC input operating voltages (100-127 VAC and 200-240 VAC) and current rating certified by all applicable safety agencies.

DC output voltages and current ratings.

Revision number of the ATX, SFX, etc. specification that the power supply meets.

Access warning text (“Do not remove this cover. Trained service personnel only. No user serviceable components inside.”) must be in English, German, Spanish, French, Chinese, and Japanese with universal warning markings.

Power Supplies are recommended list the supported Required or Recommended Timing values (T1 and T3) in product documentation. There are two levels of timing for T1 and T3 a power supply can support as detailed in Figure 4-2. This will help system integrators and end users know the T1 and T3 timing values.

12VHPWR connector/cable harnesses that are hard-wired to the power supply shall be labeled indicating the maximum power supported according to the Sense0/1 encoding implemented for each connector. If the Sense lines are dynamic (can change in standby mode only), the product documentation must describe the power levels supported based on the number of PCIe* Add-in Cards connected. Sense0/1 are described in Section Section 3.3.1 of this document. An example of these labels are illustrated in Figure 5-1 below.

Figure 5-1: 12VHPWR Connector Labeling Example