Intel® Core™ Ultra 200S, Intel® Core™ Ultra 200S Plus ,Intel® Core™ Ultra 200HX and 200HX Plus Series Processors

Datasheet, Volume 1 of 2

ID Date Version Classification
832586 03/17/2026 Public
Document Table of Contents
LAM

VCCPRIM_1P8 DC Specifications

Processor VCCPRIM_​1P8_​PROC Supply DC Voltage and Current Specifications

Segment Symbol Parameter Minimum Typical Maximum Unit Note
All VCCPRIM_​1P8_​PROC VCCPRIM_​1P8 _​PROC

Power Rail Voltage

- 1.8 - V 2,3,4
All TOBVCCPRIM_​1P8_​PROC Voltage Tolerance - - ±5 % 2,3
All IccMAXVCCPRIM_​1P8_​PROC Maximum Current - - 0.44 A 3
Notes:
  1. All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  2. Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
  3. No requirement on the breakdown of AC versus DC noise.
  4. The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe

Processor VCCPRIM_​1P8_​PROC_​SOC Supply DC Voltage and Current Specifications

Segment Symbol Parameter Minimum Typical Maximum Unit Note
All VCCPRIM_​1P8_​PROC_​SOC VCCPRIM_​1P8 _​PROC_​SOC Power Rail Voltage - 1.8 - V 2,3,4
All TOBVCCPRIM_​1P8_​PROC_​SOC Voltage Tolerance - - ±5 % 2,3
All IccMAXVCCPRIM_​1P8_​PROC_​SOC Maximum Current - - 1.21 A 3
Notes:
  1. All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  2. Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
  3. No requirement on the breakdown of AC versus DC noise.
  4. The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe

Processor VCCPRIM_​1P8_​PROC_​DDR Supply DC Voltage and Current Specifications

Segment Symbol Parameter Minimum Typical Maximum Unit Note
All VCCPRIM_​1P8_​PROC_​DDR VCCPRIM_​1P8 _​PROC_​DDR Power Rail Voltage - 1.8 - V 2,3,4
All TOBVCCPRIM_​1P8_​PROC_​DDR Voltage Tolerance - - ±5 % 2,3
All IccMAXVCCPRIM_​1P8_​PROC_​DDR Maximum Current - - 0.15 A 3
Notes:
  1. All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  2. Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
  3. No requirement on the breakdown of AC versus DC noise.
  4. The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe

Processor VCCPRIM_​1P8_​PROC_​FLTRA Supply DC Voltage and Current Specifications

Segment Symbol Parameter Minimum Typical Maximum Unit Note
All VCCPRIM_​1P8_​PROC_​FLTRA VCCPRIM_​1P8_​PROC_​FLTRA Power Rail Voltage - 1.8 - V 2,3,4
All TOBVCCPRIM_​1P8_​PROC_​FLTRA Voltage Tolerance - - ±5 % 2,3
All IccMAXVCCPRIM_​1P8_​PROC_​FLTRA Maximum Current - - 168 mA 3
Notes:
  1. All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  2. Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
  3. No requirement on the breakdown of AC versus DC noise.
  4. The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe