Processor VCCPRIM_1P8_PROC Supply DC Voltage and Current Specifications
Segment
Symbol
Parameter
Minimum
Typical
Maximum
Unit
Note
All
VCCPRIM_1P8_PROC
VCCPRIM_1P8 _PROC
Power Rail Voltage
-
1.8
-
V
2,3,4
All
TOBVCCPRIM_1P8_PROC
Voltage Tolerance
-
-
±5
%
2,3
All
IccMAXVCCPRIM_1P8_PROC
Maximum Current
-
-
0.44
A
3
Notes:
All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
No requirement on the breakdown of AC versus DC noise.
The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe
Processor VCCPRIM_1P8_PROC_SOC Supply DC Voltage and Current Specifications
Segment
Symbol
Parameter
Minimum
Typical
Maximum
Unit
Note
All
VCCPRIM_1P8_PROC_SOC
VCCPRIM_1P8 _PROC_SOC Power Rail Voltage
-
1.8
-
V
2,3,4
All
TOBVCCPRIM_1P8_PROC_SOC
Voltage Tolerance
-
-
±5
%
2,3
All
IccMAXVCCPRIM_1P8_PROC_SOC
Maximum Current
-
-
1.21
A
3
Notes:
All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
No requirement on the breakdown of AC versus DC noise.
The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe
Processor VCCPRIM_1P8_PROC_DDR Supply DC Voltage and Current Specifications
Segment
Symbol
Parameter
Minimum
Typical
Maximum
Unit
Note
All
VCCPRIM_1P8_PROC_DDR
VCCPRIM_1P8 _PROC_DDR Power Rail Voltage
-
1.8
-
V
2,3,4
All
TOBVCCPRIM_1P8_PROC_DDR
Voltage Tolerance
-
-
±5
%
2,3
All
IccMAXVCCPRIM_1P8_PROC_DDR
Maximum Current
-
-
0.15
A
3
Notes:
All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
No requirement on the breakdown of AC versus DC noise.
The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe
Processor VCCPRIM_1P8_PROC_FLTRA Supply DC Voltage and Current Specifications
Segment
Symbol
Parameter
Minimum
Typical
Maximum
Unit
Note
All
VCCPRIM_1P8_PROC_FLTRA
VCCPRIM_1P8_PROC_FLTRA Power Rail Voltage
-
1.8
-
V
2,3,4
All
TOBVCCPRIM_1P8_PROC_FLTRA
Voltage Tolerance
-
-
±5
%
2,3
All
IccMAXVCCPRIM_1P8_PROC_FLTRA
Maximum Current
-
-
168
mA
3
Notes:
All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
No requirement on the breakdown of AC versus DC noise.
The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe