Intel® Core™ Ultra 200S, Intel® Core™ Ultra 200S Plus ,Intel® Core™ Ultra 200HX and 200HX Plus Series Processors

Datasheet, Volume 1 of 2

ID Date Version Classification
832586 03/17/2026 Public
Document Table of Contents
LAM

VCCPRIM_VNNAON DC Specifications

Processor VCCPRIM_​VNNAON Supply DC Voltage and Current Specifications

Segment Symbol Parameter Minimum Typical Maximum Unit Note
All Processor Lines VCCPRIM_​VNNAON VCCPRIM_​VNNAON Power Rail Voltage - 0.77 - V 2,3,4
All Processor Lines TOBVCCPRIM_​VNNAON Voltage Tolerance -50 - +50 mV 2,3
S Processor Line IccMAXVCCPRIM_​VNNAON Maximum Current - - 29 A 3
HX Processor Line IccMAXVCCPRIM_​VNNAON Maximum Current - - 29 A 3
S-Plus Processor Line IccMAXVCCPRIM_​VNNAON Maximum Current - - 29 A 3
HX-Plus Processor Line IccMAXVCCPRIM_​VNNAON Maximum Current - - 29 A 3
Notes:
  1. All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  2. Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins. Keep 1st harmonic ripple ≤ 1MHz.
  3. No requirement on the breakdown of AC versus DC noise.
  4. The voltage specification requirements are measured on package pins as near as possible to the processor with an oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe

Processor VCCPRIM_​VNNAON_​FLTRA Supply DC Voltage and Current Specifications (HX Processor Line)

Segment Symbol Parameter Minimum Typical Maximum Unit Note 1
HX Processor Line VCCPRIM_​VNNAON_​FLTRA VCCPRIM_​VNNAON_​FLTRA Power Rail Voltage - 0.77 - V 2,3,4
HX Processor Line TOBVCCPRIM_​VNNAON_​FLTRA Voltage Tolerance -50 - +50 mV 2,3
HX Processor Line IccMAXVCCPRIM_​VNNAON_​FLTRA Maximum Current - - 88 mA 3
Notes:
  • All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  • Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
  • No requirement on the breakdown of AC versus DC noise.
  • The voltage specification requirements are measured on package pins as near as possible to the processor within oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe

Processor VCCPRIM_​VNNAON_​FLTRA Supply DC Voltage and Current Specifications (HX-Plus Processor Line)

Segment Symbol Parameter Minimum Typical Maximum Unit Note 1
HX-Plus Processor Line VCCPRIM_​VNNAON_​FLTRA VCCPRIM_​VNNAON_​FLTRA Power Rail Voltage - 0.77 - V 2,3,4
HX-Plus Processor Line TOBVCCPRIM_​VNNAON_​FLTRA Voltage Tolerance -50 - +50 mV 2,3
HX-Plus Processor Line IccMAXVCCPRIM_​VNNAON_​FLTRA Maximum Current - - 88 mA 3
Notes:
  • All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  • Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
  • No requirement on the breakdown of AC versus DC noise.
  • The voltage specification requirements are measured on package pins as near as possible to the processor within oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe

Processor VCCPRIM_​VNNAON_​FLTRB Supply DC Voltage and Current Specifications (HX Processor Line)

Segment Symbol Parameter Minimum Typical Maximum Unit Note 1
HX Processor Line VCCPRIM_​VNNAON_​FLTRB VCCPRIM_​VNNAON_​FLTRB Power Rail Voltage - 0.77 - V 2,3,4
HX Processor Line TOBVCCPRIM_​VNNAON_​FLTRB Voltage Tolerance -50 - +50 mV 2,3
HX Processor Line IccMAXVCCPRIM_​VNNAON_​FLTRB Maximum Current - - 88 mA 3
Notes:
  • All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  • Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
  • No requirement on the breakdown of AC versus DC noise.
  • The voltage specification requirements are measured on package pins as near as possible to the processor within oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe

Processor VCCPRIM_​VNNAON_​FLTRB Supply DC Voltage and Current Specifications (HX-Plus Processor Line)

Segment Symbol Parameter Minimum Typical Maximum Unit Note 1
HX-Plus Processor Line VCCPRIM_​VNNAON_​FLTRB VCCPRIM_​VNNAON_​FLTRB Power Rail Voltage - 0.77 - V 2,3,4
HX-Plus Processor Line TOBVCCPRIM_​VNNAON_​FLTRB Voltage Tolerance -50 - +50 mV 2,3
HX-Plus Processor Line IccMAXVCCPRIM_​VNNAON_​FLTRB Maximum Current - - 88 mA 3
Notes:
  • All specifications in this table are based on estimates and simulations or empirical data. These specifications will be updated with characterized data from silicon measurements at a later date.
  • Includes AC and DC error, where the AC noise is bandwidth limited to under 1 MHz, measured on package pins.
  • No requirement on the breakdown of AC versus DC noise.
  • The voltage specification requirements are measured on package pins as near as possible to the processor within oscilloscope set to 100 MHz bandwidth, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled into the oscilloscope probe