600 Series Chipset Family On-Package Platform Controller Hub

Datasheet, Volume 1 of 2

ID 691222
Date 01/05/2022

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

Integrated USB-C Usage

SMLink1 is used to communicate with USB-C* PD Controller on the platform to configure different modes such as USB, Display Port, Thunderbolt*, etc. When used for Integrated USB-C purposes, a soft strap must be set to indicate that integrated USB-C ports from CPU are being used.

SMLINK1 uses master mode and gets an alert signal from PMCALERT#.

Based on capabilities of different PD Controllers, re-timers needed for USB-C connector on the platform may need to be controlled by SoC also. In these cases, both PD Controller and Re-timers will be connected to SMLink1. SMLink1 is used for all USB-C connectors on the platform.

USB-C connectors are present on edges of systems and could also be on opposite ends, so (SMLink1, PMCAlert) could be routed to long distance on the motherboard provided total bus capacitance specification is met.

USB-C Re-timer control (like Firmware Load, USB-C configuration) handling depends on the number of I2C ports available on the PD controller.

If the PD controller has two I2C ports then PCH PMC will handle the Re-timer and PD controller, but if the PD controller has three or more I2C ports then PCH PMC will handle only PD controller. Re-timers can be handled by PD controller.

SMLink1 should be run at 400 kHz when used for USB-C purposes.