DSP

Thermal Sensor Accuracy (Taccuracy)

The PCH thermal sensor accuracy is:

  • ±5°C over the temperature range from 50°C to 110°C.
  • ±7°C over the temperature range from 30°C to 50°C.
  • ±10°C over the temperature range from -10°C to 30°C.
  • The sensor itself is functional, from -40°C to 130°C, no accuracy is specified for temperature range beyond 110°C or below -10°C.