Intel® 400 Series Chipset On-Package Platform Controller Hub
Online Register Database
| ID | Date | Version | Classification |
|---|---|---|---|
| 615146 | 08/09/2019 | 1.2 | Public |
ADMA Error Status (admaerrsts) – Offset 54
When the ADMA Error interrupt occur, this register holds the ADMA State in ADMA Error States field and ADMA System Address holds address around the error descriptor
| Bit Range | Default | Access | Field Name and Description |
|---|---|---|---|
| 6:3 | - | - | Reserved
|
| 2 | 0h | RO | ADMA Length Mismatch Error (admaerrsts_admalenmismatcherr) This error occurs in the following 2 cases. |
| 1:0 | 0h | RO | ADMA Error State (admaerrsts_admaerrorstate) This field indicates the state of ADMA when error is occurred during ADMA data transfer. This field never indicates 10 because ADMA never stops in this state. |