615146 | 08/09/2019 | 1.2 | Public |
Auto CMD12 Error Status (autocmderrsts) – Offset 3c
Bit Range | Default | Access | Field Name and Description |
---|---|---|---|
14:8 | - | - | Reserved
|
7 | 0h | RO | Command Not Issued By Auto CMD12 Error (autocmderrsts_nexterror) Setting this bit to 1 means CMD_wo_DAT is not executed due to an Auto CMD12 error(D04- D01) in this register. This bit is set to 0 when Auto CMD Error is generated by Auto CMD23 |
6:5 | - | - | Reserved
|
4 | 0h | RO | Auto CMD Index Error (autocmderrsts_indexerror) Occurs if the Command Index error occurs in response to a command. |
3 | 0h | RO | Auto CMD End Bit Error (autocmderrsts_endbiterror) Occurs when detecting that the end bit of command response is 0. |
2 | 0h | RO | Auto CMD CRC Error (autocmderrsts_crcerror) Occurs when detecting a CRC error in the command response. |
1 | 0h | RO | Auto CMD Timeout Error (autocmderrsts_timeouterror) Occurs if the no response is returned within 64 SDCLK cycles from the end bit of the command. |